MB95630H Series
MN702-00009-2v0-E FUJITSU SEMICONDUCTOR LIMITED 471
CHAPTER 22 UART/SIO
22.6 Operations and Setting Procedure Example
Figure 22.6-10 Baud Rate Calculation Formula for Using Dedicated Baud Rate Generator
Serial clock
The serial clock signal is output under control of the output for transmit data. When only
reception is performed, therefore, set transmission control (SMC2n:TXE = 1) to write dummy
transmit data to the UART/SIO serial output register. Refer to the device data sheet for the
UCKn clock value.
Baud rate value =
Machine clock (MCLK)
[bps]
2
×
×
1
2
4
8
1
:
256
UART baud rate setting register ch. n (BRSRn)
Baud rate setting (BRS[7:0])
UART prescaler select register ch. n (PSSRn)
Prescaler select (PSS[1:0])