160 Upgrade and Maintenance Manual TX140 S1
Hard disk drives / solid state drives
For further safety information, please refer to chapter "Important
information" on page 41.
In this chapter
2.5-inch HDD / SSD subsystem
"Installing 2.5-inch HDD / SSD modules" on page 163
"Removing 2.5-inch HDD / SSD modules" on page 167
"Replacing a 2.5-inch HDD / SSD module" on page 171
"Replacing the 2.5-inch HDD SAS / SATA backplane" on page 185
3.5-inch HDD subsystem
"Installing 3.5-inch HDD modules" on page 175
"Removing 3.5-inch HDD modules" on page 179
"Replacing a 3.5-inch HDD module" on page 183
"Replacing the 3.5-inch HDD SAS / SATA backplane" on page 194
7.1 Basic procedure
Solid state drives (SSDs) are always equipped before installing hard disk
drives.
Hard disk drives / solid state drives with different capacities are installed
from highest to lowest capacity.
Hard disk drives with different rotation speeds are installed from highest to
lowest speed.
When installing hard disk drives with different bus technologies (SAS or
SATA), first install SAS drives and then SATA drives.
Please refer to sections 7.2.1 and 7.3.1 for a complete overview of the
mounting sequence.
Install dummy modules into unused HDD / SSD bays.