184 Upgrade and Maintenance Manual TX140 S1
Hard disk drives / solid state drives
Ê Locate the defective HDD module as described in section "Local diagnostic
indicators on the front" on page 57.
Only applicable for removing intact HDD modules:
Ê Before removing a non-defective HDD module, put the drive into "Offline"
mode using your RAID configuration software.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide, available from the ServerView Suite DVD 2
supplied with your PRIMERGY server or online at
http://manuals.ts.fujitsu.com (EMEA market) or
http://jp.fujitsu.com/platform/server/primergy/manual/ (Japanese market)..
7.3.4.3 Removing a 3.5-inch HDD module
Ê Remove the HDD module to be replaced from the server as described in
section "Removing a 3.5-inch HDD module" on page 180.
7.3.4.4 Installing a 3.5-inch HDD module
Ê Install the new HDD module into the empty drive bay as described in section
"Installing 3.5-inch HDD modules" on page 175.
7.3.4.5 Concluding steps
Perform the following procedures to complete the task:
Ê When working on a tower server, close the HDD bay cover as described in
section "Installing the HDD bay cover" on page 84.
Ê Please observe the notes on RAID rebuild in section "Performing a RAID
array rebuild" on page 117.
Ê If applicable, close the rack door as described in section "Closing the rack
door" on page 92.