Front panel and external connectors
Ê When working on a rack-mounted server, secure it in the rack as described
in section "Sliding the server into the rack" on page 89.
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 87.
Ê Reconnect the AC power cord to the power supply unit and secure it with a
cable tie as described in section "Connecting the server to the mains" on
page 90.
Ê If applicable, close the rack door as described in section "Closing the rack
door" on page 92.
Ê Inform the customer about changed WWN and MAC addresses. For further
information, refer to section "Looking up changed MAC / WWN addresses"
on page 117.
Ê After replacing the front LAN board in a server running Linux OS, update its
MAC address in the related NIC definition file as described in section
"Updating the NIC configuration file in a Linux environment" on page 114.
Ê If applicable, restore LAN teaming configurations as described in section
"After replacing / upgrading LAN controllers" on page 120.
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section "Enabling
BitLocker functionality" on page 116.