EasyManuals Logo

Fujitsu PRIMERGY TX140 S1 Upgrade And Maintenance Manual

Fujitsu PRIMERGY TX140 S1
588 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #470 background imageLoading...
Page #470 background image
470 Upgrade and Maintenance Manual TX140 S1
System board and components
Ê Reinstall the fan module as described in section "Installing the fan module"
on page 209.
Ê Close the side / top cover as described in section "Mounting the top cover"
on page 80 (rack server) or "Mounting the side cover" on page 85 (tower
server).
Ê If applicable, activate TPM functionality in the system BIOS under Security >
TPM (Security Chip) Setting > Security Chip. For more information, refer to the
"D3049 BIOS Setup Utility for PRIMERGY TX140 S1 / TX120 S3 Reference
Manual".
Ê When working on a rack-mounted server, secure it in the rack as described
in section "Sliding the server into the rack" on page 89.
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 87.
Ê Reconnect all external cables.
Ê Reconnect the AC power cord to the power supply unit and secure it with a
cable tie as described in section "Connecting the server to the mains" on
page 90.
Ê If applicable, close the rack door as described in section "Closing the rack
door" on page 92.
Ê Update the system board BIOS and iRMC to the latest version as described
in section "Updating or recovering the system board BIOS and iRMC" on
page 100.
Ê Verify whether the backup data on the Chassis ID EPROM has been
restored to the system board as described in section "Verifying system
information backup / restore" on page 104.
Ê If customer BIOS settings are not restored automatically, please change the
settings manually (using the information collected during "preliminary
steps"). If you couldn't determine the BIOS version, ask the customer to
reconfigure all BIOS settings and the password.
V CAUTION!
The system event log entry Chassis IDPROM: Restore
successful (see section "Verifying system information
backup / restore" on page 104) is not valid if you updated the system
board BIOS from version 1.15.0 or below to version 1.18.0 or above.

Table of Contents

Other manuals for Fujitsu PRIMERGY TX140 S1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX140 S1 and is the answer not in the manual?

Fujitsu PRIMERGY TX140 S1 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX140 S1
CategoryServer
LanguageEnglish

Related product manuals