EasyManuals Logo

Fujitsu PRIMERGY TX140 S1 Upgrade And Maintenance Manual

Fujitsu PRIMERGY TX140 S1
588 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
TX140 S1 Upgrade and Maintenance Manual
Contents
5.1.3 Removing backup and optical disk media . . . . . . . . . . . . 96
5.1.4 Verifying and configuring the backup software solution . . . . . 96
5.1.5 Note on server maintenance in a Multipath I/O environment . . 97
5.1.6 Switching on the ID indicator . . . . . . . . . . . . . . . . . . 99
5.2 Completing the maintenance task . . . . . . . . . . . . . . . 100
5.2.1 Updating or recovering the system board BIOS and iRMC . . . 100
5.2.1.1 Updating or recovering the system board BIOS . . . . . . . 100
5.2.1.2 Updating or recovering the iRMC . . . . . . . . . . . . . . 102
5.2.2 Verifying system information backup / restore . . . . . . . . . . 104
5.2.3 Updating RAID controller firmware . . . . . . . . . . . . . . . 105
5.2.4 Enabling Option ROM scan . . . . . . . . . . . . . . . . . . . 106
5.2.5 Verifying and configuring the backup software solution . . . . . 107
5.2.6 Resetting the boot retry counter . . . . . . . . . . . . . . . . . 108
5.2.6.1 Viewing the boot retry counter . . . . . . . . . . . . . . . . 108
5.2.6.2 Resetting the boot retry counter . . . . . . . . . . . . . . . 108
5.2.7 Enabling SVOM boot watchdog functionality . . . . . . . . . . 110
5.2.8 Enabling replaced components in the system BIOS . . . . . . . 111
5.2.9 Verifying the memory mode . . . . . . . . . . . . . . . . . . . 111
5.2.10 Verifying the system time settings . . . . . . . . . . . . . . . . 112
5.2.11 Viewing and clearing the System Event Log (SEL) . . . . . . . 113
5.2.11.1 Viewing the SEL . . . . . . . . . . . . . . . . . . . . . . . 113
5.2.11.2 Clearing the SEL . . . . . . . . . . . . . . . . . . . . . . . 114
5.2.12 Updating the NIC configuration file in a Linux environment . . . 114
5.2.13 Enabling BitLocker functionality . . . . . . . . . . . . . . . . . 116
5.2.14 Performing a RAID array rebuild . . . . . . . . . . . . . . . . . 117
5.2.15 Looking up changed MAC / WWN addresses . . . . . . . . . . 117
5.2.15.1 Looking up MAC addresses . . . . . . . . . . . . . . . . . 117
5.2.15.2 Looking up WWN addresses . . . . . . . . . . . . . . . . . 118
5.2.16 Using the Chassis ID Prom Tool . . . . . . . . . . . . . . . . . 119
5.2.17 Configuring LAN teaming . . . . . . . . . . . . . . . . . . . . 119
5.2.17.1 After replacing / upgrading LAN controllers . . . . . . . . . 120
5.2.17.2 After replacing the system board . . . . . . . . . . . . . . . 120
5.2.18 Switching off the ID indicator . . . . . . . . . . . . . . . . . . 120
5.2.19 Specifying the chassis model . . . . . . . . . . . . . . . . . . 121
6 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . 123
6.1 Standard power supply . . . . . . . . . . . . . . . . . . . . 124
6.1.1 Replacing the standard power supply unit . . . . . . . . . . . . 124
6.1.1.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 124
6.1.1.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 124

Table of Contents

Other manuals for Fujitsu PRIMERGY TX140 S1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX140 S1 and is the answer not in the manual?

Fujitsu PRIMERGY TX140 S1 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX140 S1
CategoryServer
LanguageEnglish

Related product manuals