Cockpit Reference Guide for the Cirrus SR2x with Perspective Touch+ by Garmin
190-02954-01 Rev. A
222
Annunciations & Alerts
Flight
InstrumentsEIS
Nav/Com/
XPDR/Audio
Flight
Management
Hazard
AvoidanceAFCS
Additional
FeaturesAnnun/AlertsAppendixIndex
Flight
InstrumentsEAS
Audio and
CNS
Flight
Management
Hazard
AvoidanceAFCS
Additional
Features
Abnormal
OperationAnnun/AlertsAppendixIndex
System Message Comments
CHECK CRS – Database
course for LOC1 / [LOC ID]
is [CRS]°.
Selected course for LOC1 differs from published localizer course by more
than 10 degrees.
CHECK CRS – Database
course for LOC2 / [LOC ID]
is [CRS]°.
Selected course for LOC2 differs from published localizer course by more
than 10 degrees.
CHECK NAV – Approach
ID mismatch / <LOC>
Selected course for LOC2 differs from published localizer course by more
than 10 degrees.
CHECKLIST DATABASE
ERROR – See GTC1’s
database page for details.
The GTC database has an error.
CHECKLIST DATABASE
ERROR – See GTC2’s
database page for details.
The GTC database has an error.
CNFG MODULE – PFD1
configuration module is
inoperative.
The specified GDU configuration module backup memory has failed. The
system should be serviced.
COM #1 INOP: CAL –
Factory COM Calibration
Lost or Corrupted.
COM 1 calibration version error. Check COM calibration.
COM #1 INOP: CRNT –
Check COM Current.
COM 1 current is low. Check COM current.
COM #1 INOP: INTRL –
COM Internal Fault.
COM 1 has an internal fault.
COM #1 INOP - SYNTH –
COM Synthesizer Lock Fault.
COM 1 has a synthesizer lock fault.
COM #1 INOP - VOLT –
Check COM Voltage.
COM 1 has low voltage.
COM #2 INOP: CAL –
Factory COM Calibration
Lost or Corrupted.
COM 2 calibration version error. Check COM calibration.
COM #1 REDUCED TX
POWER – Reduced COM
transmit power.
COM 1 has a reduced transmission power.
COM #2 INOP: CRNT –
Check COM Current.
COM 2 current is low. Check COM current.
COM #2 INOP: INTRL –
COM Internal Fault.
COM 2 has an internal fault.