Do you have a question about the GE 9100c and is the answer not in the manual?
Provides a general overview of the 9100c anesthesia machine and ventilator.
Explains the flow of gases within the anesthesia machine.
Details how gas flows through the breathing system.
Describes the 9100c ventilator as a microprocessor-based system.
Lists and describes key features and capabilities of the 9100c ventilator.
Highlights key safety features of the 9100c ventilator for user protection.
Identifies the major components of the 9100c ventilator.
Details the components that make up the display module.
Describes the location and purpose of the Control Sample Board.
Lists the hardware components that comprise the pneumatic Vent Engine.
Explains the electronic and electrical subsystems of the ventilator.
Lists the electronic/electrical subassemblies and modules of the ventilator.
Explains how the power supply receives AC input and outputs DC voltage.
Details the function and specifications of the sealed lead acid battery.
Describes the two positions of the system switch: On and Standby.
Explains the functions and circuit types of the Control Sample Board.
Describes the functions of the Display Monitor Board.
Details the mechanical subsystems of the ventilator.
Explains the path and pressure of drive gas entering the Vent Engine.
Describes the function of the pressure regulator in the Vent Engine.
Explains how the inspiratory flow control valve is cycled and modulates gas.
Details the function of the exhalation valve for pressure control.
Explains the roles of the reservoir and bleed resistor in the Vent Engine.
Describes the function of the pressure relief valve in the bellows assembly.
Explains the function of the Mechanical Overpressure Valve (MOPV).
Details the purpose of the free breathing valve in assisting spontaneous breathing.
Explains how the flow sensor measures VT and its connection.
Lists required service mode calibrations after servicing the 9100c ventilator.
Provides guidelines for inspecting the equipment before testing.
Details procedures for testing pipeline and cylinder gas supplies.
Outlines tests for verifying the proper functioning of flow controls.
Details flow control tests when O2 monitoring is included.
Details flow control tests when O2 monitoring is not included.
Describes how to test the pressure relief valve for the vaporizer manifold.
Details the procedure for testing the O2 supply alarm.
Describes how to perform a test on the O2 flush function.
Outlines the procedure for testing vaporizer back pressure.
Details procedures for performing low-pressure leak tests.
Provides steps for performing a negative low-pressure leak test.
Details the procedure for conducting a positive low-pressure leak test.
Describes how to test various system alarms.
Details tests for the breathing system's functionality and leaks.
Outlines the procedure for testing the system's response to power failure.
Describes electrical safety tests for leakage current and grounding.
Explains the self-tests included in the 9100c Ventilator software.
Details how to enter and use the Service Mode for testing and calibration.
Shows how to view ventilator software versions and system time.
Lists the diagnostic tests and tools available for individual subsystems.
Displays discrete binary signals associated with machine switch positions.
Shows the battery charge status and operational mode.
Tests keyboard button presses and rotary encoder functionality.
Allows observation of self-tests and their results on the screen.
Manually controls valves and observes pressure/flow measurements.
Tests for leaks in the ventilator portion of the breathing system.
Covers service-level calibrations for maintaining accuracy.
Calibrates the airway pressure sensor to zero any offset.
Calculates a gain coefficient for the airway pressure transducer.
Calibrates the O2 sensor, accounting for altitude settings.
Details the procedure for calibrating the PEEP Valve.
Determines the zero value for inspiratory and expiratory flow transducers.
Details the procedure for calibrating the Inspiratory Flow Valve.
Calibrates the flow sensor for positive flow measurements.
Calibrates the flow sensor for negative flow measurements.
Explains how to enter the calibration coefficient value.
Covers system configuration and software upgrades.
Shows how to upgrade the ventilator's software with additional features.
Provides directions for performing a software upgrade using a USB disk.
Explains how to set the specific language for normal operation.
Allows setting the altitude tailored to the specific machine location.
Guides on accessing and testing cylinder regulators.
Provides instructions for setting up the test environment for cylinder regulators.
Outlines Test A for drive gas regulators and Test B for other gases.
Explains how to adjust cylinder regulators to meet pressure specifications.
Details testing and adjusting low-pressure regulators.
Details the procedure for testing and adjusting low-pressure regulators.
Explains that the hypoxic guard is not serviceable and needs replacement if malfunctioning.
Covers procedures for zeroing and checking the accuracy of the airway pressure gauge.
Provides step-by-step instructions to zero the airway pressure gauge.
Describes how to check the accuracy of the airway pressure gauge.
Provides a checklist for installing the 9100c system.
Outlines the planned maintenance schedule and procedures.
Lists parts replacement and machine checks for 12-month intervals.
Lists parts replacement in addition to 12-month requirements for 24-month intervals.
Details the maintenance procedure for the free breathing valve.
Explains how to adjust the drive gas regulator.
Details the test procedure for the MOPV pressure relief valve.
Outlines the test procedure for the exhalation valve relief valve.
Provides a guide to common problems and their probable causes and actions.
Guides on isolating leaks within the breathing system.
Tests for leaks in Vent Mode and Bag Mode components.
Presents a table of symptoms, probable causes, and recommended actions.
Covers alarm and shutdown messages, their causes, and service actions.
Advises on recording current function upgrade options before replacing the DMB.
Explains how to gather information and obtain a key code for software features.
Details steps to activate function upgrade options after replacing the DMB.
Instructs on loading the correct software revision after replacing the CSB.
Provides directions for installing software upgrades.
Details the procedure for safely releasing gas pressure from the machine.
Explains how to remove rear panels to access internal components.
Provides steps to remove the large and small upper rear panels.
Details how to remove the lower access panel for transformer access.
Provides steps for removing the tabletop to access components.
Details how to remove the upper shelf for access.
Guides on replacing components within the pipeline inlet manifold.
Details how to replace the pipeline inlet filter.
Outlines the procedure for replacing the pipeline inlet check valve.
Provides steps for replacing the inlet manifold.
Details servicing procedures for cylinder supply modules.
Details the correct tightening procedure for high-pressure tube fittings.
Guides on how to replace the entire cylinder regulator module.
Outlines the procedure for replacing the cylinder inlet filter.
States that the cylinder check valve is not replaceable and requires module replacement.
Outlines the procedure for replacing the system switch assembly.
Provides steps for replacing the O2 supply switch.
Details the checkout procedure after replacing the O2 supply switch.
Provides steps for removing and replacing the flowmeter module.
Guides on repairing or replacing parts of the vaporizer manifold.
Details how to repair the manifold port valve.
Describes the checkout procedure for the manifold port valve after replacement.
Outlines the procedure for replacing the vaporizer manifold check valve.
Details how to replace the vaporizer pressure relief valve.
Provides steps for replacing the vaporizer manifold.
Covers servicing the ACGO switch.
Details the removal and replacement of the ACGO switch.
Explains how to clean or replace the ACGO port flapper valve.
Guides on replacing components of the breathing system.
Provides steps for replacing the APL valve.
Details how to replace the Bag/Vent switch assembly.
Outlines the procedure for replacing the bag port.
Provides steps for replacing the disc seat and o-ring for check valves.
Details the procedure for replacing the EZchange Canister spring.
Provides instructions for replacing the machine's casters.
Outlines the procedure for replacing the task light switch.
Details how to replace the display module and its associated cable.
Covers servicing the display module and its components.
Provides steps for opening the display module to access internal components.
Details how to disconnect cables and remove the display monitor board.
Explains how to replace speakers, backlight inverter, and rotary encoder.
Covers servicing the Vent Engine and its components.
Provides steps to disconnect hoses and remove the Vent Engine.
Guides on replacing various components within the Vent Engine.
Lists service tools and test devices required for maintenance.
Lists specific test devices and their stock numbers.
Illustrates and lists various test tools and their stock numbers.
Identifies external components visible from the front of the machine.
References specific sections for front view external components.
Identifies external components visible from the rear of the machine.
Lists parts for the front panel, including gauges and the system switch.
Lists parts associated with the rear panel of the machine.
Identifies components related to the AC power system.
Lists various fittings for pipeline gas inlets.
Details parts related to cylinder gas supplies and inlets.
Lists components of the vaporizer manifold assembly.
Identifies parts of the flowmeter module.
Lists components found within the tabletop pan.
Lists parts for the ACGO Selector Switch.
Identifies parts related to the breathing system interface.
Lists components of the breathing system.
Lists components of the breathing system visible from the front.
Lists components of the breathing system visible from the rear.
Lists all parts associated with the APL Valve.
Lists all parts associated with the Bag/Vent Switch.
Lists parts for the absorber canister assembly.
Lists parts for the shelf canister interface module.
Lists all parts associated with the exhalation valve.
Lists all parts of the bellows assembly.
Lists parts for the flow sensor assembly.
Lists parts for the EZchange Canister System.
Identifies parts of the Vent Engine.
Lists components of the display module.
Lists the individual components of the display module.
Lists parts for the display keyboard and LCD assembly.
Illustrates and lists various Legris quick-release fittings and their stock numbers.
Lists part numbers and specifications for various tubings used in the system.
Lists part numbers for various cables and harnesses.
Identifies components for Passive and Adjustable AGSS.
Lists components for the passive AGSS system.
Lists components for the adjustable AGSS system.
Lists components for the active AGSS system.
Lists parts for the CGO Valve and AGSS installation components.
Shows the overall system connection block diagram.
Illustrates the gas scavenging circuits of the system.
Shows the physical path of gas tubing connections.
Illustrates the wiring harnesses connecting various modules.
Depicts the functional block diagram of the ventilator system.
Shows the block diagram of the control sample board.
Illustrates the block diagram of the display monitor board.
Provides the schematic for the AC inlet module (100-120 V).
Provides the schematic for the AC inlet module (220-240 V).
| Brand | GE |
|---|---|
| Model | 9100c |
| Category | Medical Equipment |
| Language | English |
Loading...