S1002.PRO_mz12PRO_Teil2_V1sh
If phases are defined, the currently selected phase is displayed to the
left of the display, and the respective settings only apply to the dis-
played phase.
Dual Rate
Dual rate acts directly on the corresponding control function, irre-
spective of whether this affects a single RC component or via arbi-
trarily complex mixing and coupling functions on several compo-
nents.
This option can be selected in two stages and can be set between 0
and 125% of the normal control travel per switching position.
Expo
Expo also acts directly on the corresponding control function, irre-
spective of whether this affects a single RC component or via arbi-
trarily complex mixing and coupling functions on several compo-
nents.
Expo allows a more sensitive control of the model in the central posi-
tion of the respective control function (roll, elevation and tail) for
values greater than 0% without having to do without the complete
deflection in the end position of the control stick.
Conversely, the effect of the control around neutral position increases
for values less than 0% and decreases in the direction of the full
deflection.
The degree of this control travel influence can be switched over two
stages and can be set between -100% and +100% for each switching
position, where 0% corresponds to the normal linear control charac-
teristic.
Combining Dual Rate and Expo
If both dual rate and expo values are set in one line, the settings are
overlapped accordingly.
Programming step-by-step
1. Switch to the desired phase.
2. Use the selection buttons to select the line to be set and, if nec-
essary, the value field to be set.
If a switch is to be assigned to a line, then the procedure
should start with the switch assignment.
3. Push the ENT key.
4. Use the selection keys to set the desired value or activate the
switch.
5. Proceed appropriately with the remaining value fields.
6. Push the ESC key to stop the procedure.
100%
100%
100%
0%
0%
0%
AI
EL
RU
DUAL EXPO
–––
–––
–––
normal
100%
100%
100%
0%
0%
0%
AI
EL
RU
DUAL EXPO
–––
–––
–––
normal