EasyManuals Logo

GRAUPNER mz-12 PRO User Manual

GRAUPNER mz-12 PRO
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
49 / 116
S1002.PRO_mz12PRO_Teil2_V1sh
Other receiver binding
The model memory is already bound. This binding is to be replaced
by another. After the binding process has been initiated, the mes-
sage "Switch off HF" appears in the display instead of "BIND".
Push the ENT key.
Use the selection buttons to move two lines down, to the line "RF
module".
Push the ENT key.
As described at the very end of the "RF module" section, turn the
RF module OFF.
Delete a binding
As described in "Binding step-by-step", trigger a binding operation
WITHOUT setting a receiver in the binding mode beforehand.
Range test
When the range test starts, the output of the transmitter decreases
significantly. A practical functional test can therefore be performed
at a distance of less than 100 m. After the the end of the range test,
the transmitter switches back to full output power and the range
test signal tone stops.
Eventually ask for help.
Range test step-by-step
1. Install the receiver, which preferably has already been bound to
the transmitter, in the model.
2. Switch the transmitter on and wait until the receiver indicate
according to the manual a correct function connection. Only now
the servos can be moved.
3. Place the model on a flat surface (cement, mowed lawn or ground)
so that the receiver antennas are at least 15 cm above the ground.
It may therefore be necessary to place a support underneath the
model during the test.
4. Hold the transmitter at hip level at a slight distance from your
body. However, do not aim directly at the model with the antenna
integrated into the right handle of the transmitter, but tilt the
transmitter downwards or turn to the side so that this handle is
approximately at right angles to the model during the test oper-
ation.
5. Push the ENT key.
The time display begins to run backwards and a beep sounds
throughout the entire range test.
6. During the 90 seconds, walk away from the model and move the
sticks.
If you notice an interruption in the connection at any time
within a distance of about 50 m, try to reproduce it.
Control mode
1
–––
Timers 0:00
Rcv output
Bind
–––
Range test
99s
SWITCH
RF
OFF
OK
Control mode
1
–––
Timers 0:00
Rcv output
Bind
–––
Range test
99s
Antenna integrated
in the handle

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GRAUPNER mz-12 PRO and is the answer not in the manual?

GRAUPNER mz-12 PRO Specifications

General IconGeneral
BrandGRAUPNER
Modelmz-12 PRO
CategoryRadio
LanguageEnglish

Related product manuals