3−87
Input Function Summary Table
Option
Code
Terminal
Symbol
Function Name Description
44
BOK Brake confirmation ON
Brake wait time (b124) is valid
OFF
Brake wait time (b124) is not valid
46
LAC LAD cancellation ON Set ramp times are ignored. Inverter output
immediately follows the freq. command.
OFF Accel. and/or decel. is according to the set ramp time
47
PCLR Pulse counter clear ON Clear the position deviation data
OFF Maintain the position deviation data
50
ADD ADD frequency enable ON
Adds the A145 (add frequency) value to the output
frequency
OFF
Does not add the A145 value to the output frequency
51
F-TM Force Terminal Mode ON Force inverter to use input terminals for output
frequency and Run command sources
OFF
Source of output frequency set by A001 and source of
Run command set by A002 is used
52
ATR Enable torque
command input
ON Torque control command input is enabled
OFF Torque control command input is disabled
53
KHC Clear watt-hour data ON Clear watt-hour data
OFF No action
56
MI1 General purpose input
(1)
ON General purpose input (1) is made ON under EzSQ
OFF General purpose input (1) is made OFF under EzSQ
57
MI2 General purpose input
(2)
ON General purpose input (2) is made ON under EzSQ
OFF General purpose input (2) is made OFF under EzSQ
58
MI3 General purpose input
(3)
ON General purpose input (3) is made ON under EzSQ
OFF General purpose input (3) is made OFF under EzSQ
59
MI4 General purpose input
(4)
ON General purpose input (4) is made ON under EzSQ
OFF General purpose input (4) is made OFF under EzSQ
60
MI5 General purpose input
(5)
ON General purpose input (5) is made ON under EzSQ
OFF General purpose input (5) is made OFF under EzSQ
61
MI6 General purpose input
(6)
ON General purpose input (6) is made ON under EzSQ
OFF General purpose input (6) is made OFF under EzSQ
62
MI7 General purpose input
(7)
ON General purpose input (7) is made ON under EzSQ
OFF General purpose input (7) is made OFF under EzSQ
65
AHD Analog command hold ON Analog command is held
OFF Analog command is not held
66
CP1 Multistage-position
switch (1)
ON Multistage position commands are set according to
the combination of these switches.
OFF
67
CP2 Multistage-position
switch (2)
ON
OFF
68
CP3 Multistage-position
switch (3)
ON
OFF
69
ORL Limit signal of homing ON Limit signal of homing is ON
OFF Limit signal of homing is OFF
70
ORG Trigger signal of
homing
ON Starts homing operation
OFF No action
73
SPD Speed/position
changeover
ON Speed control mode
OFF Position control mode