SET
Group "d"
Func. code display
V U
Group "F"
Func. code display
F002
Save
Data display (F001 to F003)
Data does not blink because of real time synchronizing
: Saves the data in EEPROM and returns to func. code display.
: Returns to func. code display without saving data.
SET
ESC
Func. code display
: Jumps to the next group
ESC
: Moves to data display
Func. code display
Group "A"
Func. code display
A002
Data display
When data is changed, the display starts blinking, which means that
new data has not been activated yet.
ESC
SET
: Cancels the data change and returns to func. code display.
: Saves the data in EEPROM and returns to func. code display.
ESC
Refer to 2-34 for further information.
Press the both up and down key at the same
time in func. code or data display, then
single-digit edit mode will be enabled.
V
U
NOTE: Pressing the [ESC] key will make the display go to the top of next function
group, regardless the display contents. (e.g. A021 Æ [ESC] Æ b001)