2−28
[Setting example]
After power ON, changing from 0.00 display to change the b083 (carrier frequency) data.
Function code dxxx are for monitor and not possible to change.
Function codes Fxxx other than F004 are reflected on the performance just after changing the data
(before pressing SET key), and there will be no blinking.
When a function code is shown… When a data is shown…
ESC key
Move on to the next function group
Cancels the change and moves back to
the function code
SET key Move on to the data display
Fix and stores the data and moves back
to the function code
U key Increase function code Increase data value
V key Decrease function code Decrease data value
Note
Keep pressing for more than 1 second leads to d001 display, regardless the display situation. But note that
the display will circulates while keep pressing the [ESC] key because of the original function of the key.
(e.g. F001 Æ A001 Æ b001 Æ C001 Æ …Æ displays 50.00 after 1 second)
b001
b083 5.0
Display is solid lighting.
12.0
F001
d001
0.00
c Data of will be shown on the
display after the first power ON
d Press [ESC] key to show
the function code
e Press [ESC] key to move on to the function group
f Press [ESC] key twice to move on to the function group
g Press Up key to change increase function code ( Æ
h Press SET key to display the data of
d001
F001
b001.
b001 b083)
b083
ESC
U
and save the data
When data is changed, the display
starts blinking, which means that new
data has not been activated yet.
V
:Fix and stores the data and moves back to the function code
:Cancels the change and moves back to the function code
SET