Smart Array  240  
Table 15-100  HPSA_DeviceIndication: Physical Drive status changed to OK 
Property name  Property implementation 
•  VariableNames[0]: FailureDescription 
VariableNames 
•  VariableNames[1]: LastFailureDescription 
•  VariableNames[2]: DriveInterface 
•  VariableTypes[0]: 1 (String) 
VariableTypes 
•  VariableTypes[1]: 1 (String) 
•  VariableTypes[2]: 4 (uint16) 
•  VariableValues[0]: Short Description of failure 
VariableValues 
•  VariableValues[1]: Short Description of last failure
•  3 (Enclosure) for c-Class blade systems 
ImpactedDomain 
•  4 (System) for all other systems 
When ImpactedDomain is 3 (Enclosure), the properties 
indicated with (*) are populated. 
BladeBay *  HP_BladeCSLocation.LocationInformation[0] 
BladeName *  HP_ComputerSystem.Name 
EnclosureName *  HP_BladeEnclosureCS.Name 
RackName *  Rack name if one exists 
RackUID *  Rack Unique Identifier if one exists 
SystemVirtualSerialNumber Conditional property containing the virtual system 
serial number string when running in a Virtual Connect 
environment. 
SystemVirtualUUID Conditional property containing the virtual system 
UUID when running in a Virtual Connect environment. 
HP_HardwareIndication 
HWFirmwareVersion Physical Disk firmware version string 
HWLogicalLocation  Physical Disk Location string 
For example, Port:1E Box: 1 Bay: 5 
HWPhysicalLocation  Physical Location of the Failed Drive (Bay Number) 
DeviceControllerLogicalLocation Controller Location 
For example, SmartArray 642 in Slot 2 
HWManufacturer Compaq 
HWSerialNumber  Physical Disk Serial Number 
HP_DeviceIndication 
DeviceModel  Physical Disk Model string