SCSI HBA  424  
Table 18-62  HPSCSI_DeviceIndication: Physical Drive status set to OK 
Property name  Property implementation 
HWManufacturer  Disk Manufacturer string 
HWSerialNumber  Disk Serial Number 
HP_DeviceIndication 
DeviceModel  Disk Model string 
 
18.4.2Physical Drive Status Set to ERROR 
Table 18-63  HPSCSI_DeviceIndication: Physical Drive status set to ERROR 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier GUID string generated at time of indication 
PerceivedSeverity  Severity (for example, 5 (Major)) 
IndicationTime  Time of indication 
CIM_AlertIndication 
Description  A SCSI physical drive has a status of Error. 
AlertingMangedElement  WBEM path of the HPSCSI_DiskDrive class instance 
AlertingElementFormat 2 (CIMObjectPath) 
AlertType  5 (Device Alert) 
EventID 5 
EventTime  Time of the event or time of the indication if event time 
unknown. 
ProviderName HP SCSI 
RecommendedActions  Check for failed or removed physical drives. 
SystemName  Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating 
the indication 
HP_AlertIndication 
Summary  Physical drive ERROR. 
EventCategory  6 (Primary Storage) 
ProbableCause  86 (Disk Failure) 
ProbableCauseDescription Physical Drive Error 
ProviderVersion  Provider version generating the indication, in the form: 
major.minor.revision.build. 
NetworkAddresses  A list of all the IP addresses (IPv4 and IPv6) of the 
computer system generating the indication