Ethernet Teaming 156
Table 13-24 Class: HP+EthEventSettings
Property name Property implementation
MemberRoleChanged If enabled, an event is generated when any change in
team member role is detected. Default: disabled.
MemberStatusChanged If enabled, an event is generated when any change in
team member status is detected. Default: disabled.
MonitorLANEndpoints If enabled, events related to HP_WinEthLANEndpoint
are generated. Default: disabled.
MonitorPorts If enabled, events related to HP_WinEthernetPort are
generated. Default: enabled.
MonitorRedundancySets If enabled, events related to HP_WinEthRedundancySet
are generated. Default: true.
PolInterval The longest interval between network status polls, in
seconds. Value 0 disables polling and is not
recommended. Using very low values can increase
CPU utilization. Default: 200.
13.4Supported indications
The following indications are implemented for Integrity server platforms where available. System
Ethernet Port, Ethernet Team, and Ethernet LAN Endpoint indications are described in the following.
For nonteamed Ethernet Ports, if the associated HP_EthernetMemberOfCollection.Included is False, the
following indications are disabled.
For teamed Ethernet Ports, this association does not exist. For Ethernet Teams where the association
does exist, but the Included property value is ignored, all applicable indications are enabled.
13.4.1Ethernet Team Redundancy Lost
Table 13-25 HP_AlertIndication: Ethernet Team Redundancy Lost
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 6 (Critical)
IndicationTime Time of indication
CIM_AlertIndication
Description An Ethernet team's redundancy status changed to
Redundancy Lost. All members of an Ethernet team,
except one, are failed.
AlertingManagedElement WBEM path of the Ethernet Team (HP_EthernetTeam)
reporting lost redundancy
AlertingElementFormat 2 (CIMObjectPath)

Table of Contents

Other manuals for HP Integrity BL860c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity BL860c and is the answer not in the manual?

HP Integrity BL860c Specifications

General IconGeneral
BrandHP
ModelIntegrity BL860c
CategoryServer
LanguageEnglish

Related product manuals