SCSI HBA 451
Table 18-76 HPSCSI_DeviceIndication: Temperature sensor status change OK
Property name Property implementation
DeviceModel Enclosure Model string
18.4.16Temerature Sensor Status Change Warning Condition
Note: This indication might not be generated because the SCSI firmware does not report this
indication.
Table 18-77
HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 4 (Minor)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor Status
changed to Warning Condition. This indicates the
enclosure temperature is above normal, otherwise
enclosure is still operating normally.
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 308
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SCSI
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Temperature sensor status Warning Condition
EventCategory 24 (Primary Storage Cooling)
ProbableCause 51 (Temperature unacceptable)