Standalone Tape Drive Profile  500  
Table 21-36  HP_TapeDriveDeviceIndication: Degraded Drive Now Missing 
Property name  Property implementation 
SystemGUID  Platform GUID of the computer system generating the 
indication. 
•  3 (Enclosure) for c-Class blade systems 
ImpactedDomain 
•  4 (System) for all other systems 
HP_HardwareIndication 
HWFirmwareVersion  Enclosure F/W version string (It must match the 
HP_TapeDriveFirmware.VersionString) 
HWManufacturer  Enclosure Manufacturer string 
HWSerialNumber  Enclosure Serial Number (It must match the 
HP_StorageEnclosure.SerialNumber) 
HP_DeviceIndication 
DeviceModel  Enclosure Model string 
HP_TapeDriveDeviceIndication 
 
21.4.11Tape Drive Cleaning Required 
Table 21-37  HP_TapeDriveDeviceIndication: Tape Drive Cleaning Required 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier GUID string generated at indication 
PerceivedSeverity 5 (Major) 
IndicationTime  Time of indication 
CIM_AlertIndication 
Description See HPWMITapeEventMetaData.mof 
AlertingMangedElement  WBEM Path of HPSCSI_TapeDrive class instance 
AlertingElementFormat 2 (CIMObjectPath) 
AlertType  5 (Device Alert) 
EventID  511 (Tape drive cleaning required) 
EventTime  Time of the event or time of the indication if the event 
time is unknown. 
ProviderName HP Tape 
RecommendedActions See HPWMITapeEventMetaData.mof 
SystemName  Name of the computer system generating the 
indication.