SCSI HBA 447
Table 18-74 HPSCSI_DeviceIndication: Power Supply status OK
Property name Property implementation
HP_DeviceIndication
DeviceModel Enclosure Model string
18.4.14Power Supply Status DEGRADED
Note: This indication might not be generated because the SCSI firmware does not report this
indication.
Table 18-75
HPSCSI_DeviceIndication: Power Supply status DEGRADED
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Supply status has changed
to Degraded Redundancy.
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 303
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SCSI
RecommendedActions Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Power supply status Redundant Degraded
EventCategory 17 (Primary Storage Power)
ProbableCause 89 (Power Supply Failure)
ProbableCauseDescription Redundant Power Supply Degraded