SAS HBA 362
Table 17-73 HPSAS_DeviceIndication: SAS HBA in Error state
Property name Property implementation
• 3 (Enclosure) for c-Class blade systems
ImpactedDomain
• 4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure) the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWFirmwareVersion Controller firmware version string
HWLogicalLocation Controller Location string
For example, Slot 3
HWManufacturer Controller Manufacturer string
HWSerialNumber Controller Serial Number
HP_DeviceIndication
DeviceModel Controller Model string
17.4.3Physical Drive Status OK
Table 17-74 HPSAS_DeviceIndication: Physical Drive status OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed from non-OK to
OK.
AlertingMangedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)