SCSI HBA  443  
Table 18-72  HPSCSI_DeviceIndication: Controller status ERROR 
Property name  Property implementation 
DeviceModel  Controller Model string 
 
18.4.12Power Supply Status NOT REDUNDANT 
Note: This indication might not be generated because the SCSI firmware does not report this 
indication. 
Table 18-73 
 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier GUID string generated at time of indication 
PerceivedSeverity 5 (Major) 
IndicationTime  Time of indication 
CIM_AlertIndication 
Description  A Storage Enclosure Power Supply status has changed 
to non-redundant. 
AlertingMangedElement  WBEM path of the HPSCSI_StorageEnclosureProcessor 
class instance 
AlertingElementFormat 2 (CIMObjectPath) 
AlertType  5 (Device Alert) 
EventID 301 
EventTime  Time of the event or time of the indication if event time 
unknown. 
ProviderName HP SCSI 
RecommendedActions  Check status of all enclosure power supplies. Ensure 
that power supplies have not failed. Add or replace 
power supplies as necessary. 
SystemName  Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating 
the indication 
HP_AlertIndication 
Summary  SCSI Storage Enclosure operating with no Redundant 
Power Supply 
EventCategory  17 (Primary Storage Power) 
ProbableCause  88 (Loss of Redundancy) 
ProbableCauseDescription  Redundant Power Supply Status Changed to Non-
Redundant