Smart Array  241  
15.4.2Physical Drive Status Changed to ERROR 
Table 15-101  HPSA_DeviceIndication: Physical Drive status changed to ERROR 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier  GUID string generated at the time of indication 
PerceivedSeverity Severity: 
5 (Major) 
IndicationTime  Time of indication 
CIM_AlertIndication 
A physical drive status has changed to 
Error. 
Description 
AlertingMangedElement  WBEM path of the HPSA_DiskDrive class 
AlertingElementFormat 2 (CIMObjectPath) 
AlertType  5 (Device Alert) 
EventID 202 
EventTime  Time of the event or time of the indication if event time 
unknown. 
ProviderName HP SmartArray 
RecommendedActions  Check for failed or removed physical drives. 
SystemName  Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating 
the indication 
HP_AlertIndication 
Summary  Physical drive status Error. 
EventCategory  6 (Primary Storage) 
ProbableCause  86 (Disk Failure) 
ProbableCauseDescription Physical Drive Status Changed to Error 
NetworkAddresses  A list of all the IP addresses (IPv4 and IPv6) of the 
computer system generating the indication 
•  70 (Windows Server 2003 64-bit) 
OSType 
•  77 (Windows Server 2008 64-bit) 
•  103 (Windows Server 2008 R2) 
OSVersion  Operating system version of the computer system 
generating the indication in the format, 
major.minor.build 
ProviderVersion  Provider version generating the information, in the 
form: major.minor.revision.build. 
SystemFirmwareVersion Firmware version of the computer system generating 
the indication