SAS HBA  386  
17.4.15Enclosure Temperature Sensor Status Changed to 
Critical 
Table 17-86  HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier  GUID string generated at the time of indication 
PerceivedSeverity 5 (major) 
IndicationTime  Time of indication 
CIM_AlertIndication 
Description  A Storage Enclosure Temperature sensor status has 
changed to Critical. An enclosure temperature is 
reaching the maximum allowed temperature for normal 
operation. A shutdown is imminent. Action is required 
before loss of data occurs. 
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor 
AlertingElementFormat 2 (CIMObjectPath) 
AlertType  5 (Device Alert) 
EventID 309 
EventTime  Time of the event or time of the indication if event time 
unknown 
ProviderName HP SAS 
RecommendedActions  Ensure that the system is adequately ventilated. Check 
for proper room temperature and internal/external 
airflow. Add or repair fans and air baffling if 
necessary. 
SystemName  Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating 
the indication 
HP_AlertIndication 
Summary  Temperature sensor status Critical 
EventCategory  24 (Primary Storage Cooling) 
ProbableCause  51 (Temperature Unacceptable ) 
ProbableCauseDescription Temperature Status Changed to Critical 
NetworkAddresses  Contains a list of all the IP addresses (IPv4 and IPv6) of 
the computer system generating the indication 