SCSI HBA 449
Table 18-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED
Property name Property implementation
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
18.4.15Temperature Sensor Status Change OK
Note: This indication may not be generated due to the SCSI firmware does not report this indication
Table 18-76
HPSCSI_DeviceIndication: Temperature sensor status change OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor status
changed from non-OK to OK.
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 307
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SCSI
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Temperature sensor status OK
EventCategory 24 (Primary Storage Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Temperature Status Changed to OK
ProviderVersion Provider version generating the indication, in the form:
major.minor.revision.build.