SCSI HBA  449  
Table 18-75  HPSCSI_DeviceIndication: Power Supply status DEGRADED 
Property name  Property implementation 
HWSerialNumber  Enclosure Serial Number 
HP_DeviceIndication 
DeviceModel  Enclosure Model string 
 
18.4.15Temperature Sensor Status Change OK 
Note: This indication may not be generated due to the SCSI firmware does not report this indication 
Table 18-76 
 HPSCSI_DeviceIndication: Temperature sensor status change OK 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier GUID string generated at time of indication 
PerceivedSeverity 2 (Info) 
IndicationTime  Time of indication 
CIM_AlertIndication 
Description  A Storage Enclosure Temperature sensor status 
changed from non-OK to OK. 
AlertingMangedElement  WBEM path of the HPSCSI_StorageEnclosureProcessor 
class instance 
AlertingElementFormat 2 (CIMObjectPath) 
AlertType  5 (Device Alert) 
EventID 307 
EventTime  Time of the event or time of the indication if event time 
unknown. 
ProviderName HP SCSI 
RecommendedActions No action is recommended. 
SystemName  Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating 
the indication 
HP_AlertIndication 
Summary  Temperature sensor status OK 
EventCategory  24 (Primary Storage Cooling) 
ProbableCause 1 (Other) 
ProbableCauseDescription  Temperature Status Changed to OK 
ProviderVersion  Provider version generating the indication, in the form: 
major.minor.revision.build.