Table 16-37  HPFCHBA_DeviceIndication: Fibre Channel Port Status Changed to OK 
Property name  Property implementation 
SystemSerialNumber  Serial number of the computer system generating the 
indication 
SystemProductID  Product ID of the computer system generating the 
indication 
SystemModel  Model name of the computer system generating the 
indication 
SystemGUID  Platform GUID of the computer system generating the 
indication 
SystemVirtualSerialNumber Conditional property containing the virtual system 
serial number string when running in a Virtual Connect 
environment. 
SystemVirtualUUID Conditional property containing the virtual system 
UUID when running in a Virtual Connect environment. 
BladeBay *  HP_BladeCSLocation.LocationInformation[0] 
BladeName *  HP_ComputerSystem.Name 
EnclosureName *  HP_BladeEnclosureCS.Name 
•  3 (Enclosure) for c-Class blade systems 
ImpactedDomain 
•  4 (System) for all other systems 
When ImpactedDomain is 3 (Enclosure), the properties 
indicated with (*) are populated. 
RackName *  Rack name if one exists 
RackUID *  Rack Unique Identifier if one exists 
HWFirmwareVersion Controller firmware version string 
HWSerialNumber  Controller Serial Number 
HWManufacturer Name of hardware manufacturer 
DevicePermanentNameFormat PortWWN 
DevicePermanentName PortWWN 
 
16.4.2Fibre Channel Port Status changed to Link Down 
Table 16-38  HPFCHBA_DeviceIndication: Fibre Channel Port Status Changed to Link Down 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier GUID string generated at time of indication 
PerceivedSeverity 5 (Major) 
IndicationTime  Time of indication