Smart Array  293  
15.4.26Enclosure Fan Status Changed to Degraded 
Table 15-125  HPSA_DeviceIndication: Enclosure Fan status changed to Degraded 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier GUID string generated at time of indication 
PerceivedSeverity 3 (Warning) 
IndicationTime  Time of indication 
CIM_AlertIndication 
Description  A Storage Enclosure Fan status has changed to 
Degraded. An enclosure has detected there may a 
problem with one or more of the fans. 
AlertingMangedElement  WBEM path of the HPSA_StorageEnclosureProcessor 
AlertingElementFormat 2 (CIMObjectPath) 
AlertType  5 (Device Alert) 
EventID 305 
EventTime  Time of the event or time of the indication if event time 
unknown. 
ProviderName  HP Smart Array 
RecommendedActions  Ensure that the system is adequately ventilated. Check 
for proper room temperature and internal/external 
airflow. Add or repair fans and air baffling if 
necessary. 
SystemName  Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating 
the indication 
HP_AlertIndication 
Summary  Fan Status Degraded. 
EventCategory  24 (Primary Storage Cooling) 
ProbableCause  94 (Fan failure) 
ProbableCauseDescription Fan Degraded 
NetworkAddresses  A list of all the IP addresses (IPv4 and IPv6) of the 
computer system generating the indication 
•  69 (Windows Server 2003 32-bit) 
OSType 
•  70 (Windows Server 2003 64-bit) 
•  76 (Windows Server 2008 32-bit) 
•  77 (Windows Server 2008 64-bit) 
•  103 (Windows Server 2008 R2) 
OSVersion  Operating system version of the computer system 
generating the indication in the format, 
major.minor.build