Table 17-74  HPSAS_DeviceIndication: Physical Drive status OK 
Property name  Property implementation 
•  VariableTypes[0]: 1 (String) 
VariableTypes 
•  VariableTypes[1]: 4 (uint16) 
•  VariableValues[0]: Short Description of failure 
VariableValues 
•  VariableValues[1]: HPSA_DiskDrive.DriveInterface 
In some cases, the VariableValues can be N/A or “” 
(null). 
•  3 (Enclosure) for c-Class blade systems 
ImpactedDomain 
•  4 (System) for all other systems 
When ImpactedDomain is 3 (Enclosure), the properties 
indicated with (*) are populated. 
BladeBay *  HP_BladeCSLocation.LocationInformation[0] 
BladeName *  HP_ComputerSystem.Name 
EnclosureName *  HP_BladeEnclosureCS.Name 
RackName *  Rack name if one exists 
RackUID *  Rack Unique Identifier if one exists 
SystemVirtualSerialNumber Conditional property containing the virtual system 
serial number string when running in a Virtual Connect 
environment. 
SystemVirtualUUID Conditional property containing the virtual system 
UUID when running in a Virtual Connect environment. 
HP_HardwareIndication 
HWFirmwareVersion Disk firmware version string 
HWLogicalLocation  Disk Location string 
For example, Bay 3 
HWManufacturer  Disk Manufacturer string 
HWSerialNumber  Disk Serial Number 
HP_DeviceIndication 
DeviceModel  Disk Model string 
 
17.4.4Physical Drive Status ERROR 
Table 17-75  HPSAS_DeviceIndication: Physical Drive status ERROR 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier  GUID string generated at the time of indication 
PreceivedSeverity Severity 