SAS HBA 392
17.4.18Enclosure Fan Status Changed to Failure
Table 17-89 HPSAS_DeviceIndication: Enclosure Fan status changed to Failure
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan Status changed to Failure. An
enclosure has detected a failure in the fan subsystem
and there is insufficient fan capability to ensure normal
operation.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 306
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Fan status Error
EventCategory 24 (Primary Storage Cooling)
ProbableCause 94 (Fan failure)
ProbableCauseDescription Fan Failure
ProviderVersion Provider version generating the indication, in the form:
major.minor.revision.build.
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
• 69 (Windows Server 2003 32-bit)
OSType
• 70 (Windows Server 2003 64-bit)
• 77 (Windows Server 2008 32-bit)
• 77 (Windows Server 2008 64-bit)
• 103 (Windows Server 2008 R2)