Smart Array  206  
Table 15-17  Class: HPSA_EnclosureFirmware (CIM_SoftwareIdentity) 
Property name  Property implementation 
CIM_ManagedSystemElement 
Name  Storage Enclosure Processor Firmware 
CIM_LogicalElement 
Caption  Storage Enclosure Processor Firmware 
Description  Storage Enclosure Processor Firmware 
CIM_SoftwareIdentity 
ClassificationDescriptions[0] Storage Enclosure Processor Firmware 
Classifications[0] 10 (Firmware) 
InstanceID Opaque key 
Manufacturer  Enclosure vendor string 
IdentityInfoType CIM:SoftwareFamily 
IdentityInfoValue HPQ:TargetType value 
VersionString  Enclosure firmware string 
HPSA_EnclosureFirmware 
 
15.3.17HPSA_PrimordialPool 
HPSA_PrimordialPool represents the total raw storage managed by the array controller. There is one 
instance per array system. 
 
Table 15-18  Class: HPSA_PrimordialPool (CIM_StoragePool) 
Property name  Property implementation 
CIM_ManagedElement 
ElementName  Controller name and location: pool identifier (for 
example, Smart Array in Slot 3: Primordial Pool) 
CIM_ManagedSystemElement 
CIM_LogicalElement 
CIM_StoragePool 
InstanceID Opaque key 
PoolID  Controller serial number 
Primordial  Always set to TRUE 
RemainingManagedSpace  Remaining raw space on controller. This is calculated 
by summing the remaining space on all drives attached 
to the controller.