Smart Array  244  
Table 15-102  HPSA_DeviceIndication: Physical Drive status changed to REBUILDING 
Property name  Property implementation 
OSVersion  Operating system version of the computer system 
generating the indication in the format, 
major.minor.build 
ProviderVersion  Provider version generating the information, in the 
form: major.minor.revision.build. 
SystemFirmwareVersion Firmware version of the computer system generating 
the indication 
SystemSerialNumber  Serial number of the computer system generating the 
indication 
SystemProductID  Product ID of the computer system generating the 
indication 
SystemModel  Model name of the computer system generating the 
indication 
SystemGUID  Platform GUID of the computer system generating the 
indication 
•  VariableNames[0]: FailureDescription 
VariableNames 
•  VariableNames[1]: LastFailureDescription 
•  VariableNames[2]: DriveInterface 
•  VariableTypes[0]: 1 (String) 
VariableTypes 
•  VariableTypes[1]: 1 (String) 
•  VariableTypes[2]: 4 (uint16) 
•  VariableValues[0]: Short Description of failure 
VariableValues 
•  VariableValues[1]: Short Description of last failure
•  3 (Enclosure) for c-Class blade systems 
ImpactedDomain 
•  4 (System) for all other systems 
When ImpactedDomain is 3 (Enclosure), the properties 
indicated with (*) are populated. 
BladeBay *  HP_BladeCSLocation.LocationInformation[0] 
BladeName *  HP_ComputerSystem.Name 
EnclosureName *  HP_BladeEnclosureCS.Name 
RackName *  Rack name if one exists 
RackUID *  Rack Unique Identifier if one exists 
SystemVirtualSerialNumber Conditional property containing the virtual system 
serial number string when running in a Virtual Connect 
environment. 
SystemVirtualUUID Conditional property containing the virtual system 
UUID when running in a Virtual Connect environment. 
HP_HardwareIndication 
HWFirmwareVersion Physical Disk firmware version string