Smart Array  246  
Table 15-103  HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE 
Property name  Property implementation 
ProbableCause  86 (Disk Failure) 
ProbableCauseDescription Physical Drive Status Changed to Predictive Failure. 
NetworkAddresses  A list of all the IP addresses (IPv4 and IPv6) of the 
computer system generating the indication. 
•  70 (Windows Server 2003 64-bit) 
OSType 
•  77 (Windows Server 2008 64-bit) 
•  103 (Windows Server 2008 R2) 
OSVersion  Operating system version of the computer system 
generating the indication in the format, 
major.minor.build 
ProviderVersion  Provider version generating the information, in the 
form: major.minor.revision.build. 
SystemFirmwareVersion Firmware version of the computer system generating 
the indication 
SystemSerialNumber  Serial number of the computer system generating the 
indication 
SystemProductID  Product ID of the computer system generating the 
indication 
SystemModel  Model name of the computer system generating the 
indication 
SystemGUID  Platform GUID of the computer system generating the 
indication 
•  VariableNames[0]: FailureDescription 
VariableNames 
•  VariableNames[1]: LastFailureDescription 
•  VariableNames[2]: DriveInterface 
•  VariableTypes[0]: 1 (String) 
VariableTypes 
•  VariableTypes[1]: 1 (String) 
•  VariableTypes[2]: 4 (uint16) 
•  VariableValues[0]: Short Description of failure 
VariableValues 
•  VariableValues[1]: Short Description of last failure
•  3 (Enclosure) for c-Class blade systems 
ImpactedDomain 
•  4 (System) for all other systems 
When ImpactedDomain is 3 (Enclosure), the properties 
indicated with (*) are populated. 
BladeBay *  HP_BladeCSLocation.LocationInformation[0] 
BladeName *  HP_ComputerSystem.Name 
EnclosureName *  HP_BladeEnclosureCS.Name 
RackName *  Rack name if one exists 
RackUID *  Rack Unique Identifier if one exists