SAS HBA 328
Table 17-4 Class: HPSAS_StorageVolume (CIM_ StorageVolume)
Property name Property implementation
RequestedState 12 (Not Applicable)
CIM_LogicalDevice
CreationClassName HPSAS_StorageVolume
DeviceID Opaque Key
SystemCreationClassName HPSAS_ArraySystem
SystemName HPSAS_ArraySystem.Name
CIM_StorageExtent
ConsumableBlocks Total Number of blocks on the volume.
BlockSize Block Size in bytes
• 1 (for RAID 0)
DataRedundancy
• 2 (for RAID 1)
DeltaReservation Set to a value of 0
ExtentStatus[0] This will indicate extended status for the volume.
• 2 (None)
• 11 (Rebuild – Volume is currently rebuilding data)
IsBasedOnUnderlyingRedundancy False
• True – RAID 1 or above
NoSinglePointOfFailure
• False – RAID 0
NumberOfBlocks Total Number of blocks on the volume.
• 0 (RAID 0)
PackageRedundancy
• 1 (RAID 1)
• True
Primordial
• False (Provider always sets this value to False)
CIM_Storagevolume
NameFormat 7 (SNVM)
HPSAS_Storagevolume
Deleteable See HP SAS HBA Profile
FaultTolerance See HP SAS HBA Profile
OperationalStatus[0] Volume status
• 0 (Unknown)
• 2 (OK)
• 3 (Degraded) - RAID redundancy lost or
rebuilding data
• 6 (Error)
OSName Corresponding OS name for this volume

Table of Contents

Other manuals for HP Integrity BL860c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity BL860c and is the answer not in the manual?

HP Integrity BL860c Specifications

General IconGeneral
BrandHP
ModelIntegrity BL860c
CategoryServer
LanguageEnglish

Related product manuals