SCSI HBA  435  
Table 18-68  HPSCSI_DeviceIndication: Physical Drive status - Missing was Predictive Failure 
Property name  Property implementation 
BladeBay *  HP_BladeCSLocation.LocationInformation[0] 
BladeName *  HP_ComputerSystem.Name 
EnclosureName *  HP_BladeEnclosureCS.Name 
RackName *  Rack name if one exists 
RackUID *  Rack Unique Identifier if one exists 
SystemVirtualSerialNumber Conditional property containing the virtual system 
serial number string when running in a Virtual Connect 
environment. 
SystemVirtualUUID Conditional property containing the virtual system 
UUID when running in a Virtual Connect environment. 
HP_HardwareIndication 
HWFirmwareVersion Disk firmware version string 
HWLogicalLocation  Disk Location string 
HWManufacturer  Disk Manufacturer string 
HWSerialNumber  Disk Serial Number 
HP_DeviceIndication 
DeviceModel  Disk Model string 
 
18.4.8Physical Drive Status – Missing was OFFLINE 
Table 18-69  HPSCSI_DeviceIndication: Physical Drive status – Missing was OFFLINE 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier GUID string generated at time of indication 
PerceivedSeverity 2 (Information) 
IndicationTime  Time of indication 
CIM_AlertIndication 
Description  A SCSI physical drive that was located in the system 
and had a status of offline has been removed. 
AlertingMangedElement  WBEM path of the HPSCSI_DiskDrive class instance 
AlertingElementFormat 2 (CIMObjectPath) 
AlertType  5 (Device Alert) 
EventID 11 
EventTime  Time of the event or time of the indication if event time 
unknown.