EasyManua.ls Logo

HP Integrity BL860c - 5 Troubleshooting; Troubleshooting Methodology

HP Integrity BL860c
511 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System memory 86
Table 7-6 Class: HP_MemoryBoard
Property name Property implementation
HealthState Enumerator indicating the memory board health state:
0 (Unknown), when OperationalStatus[0] = 0
(Unknown)
5 (OK), when OperationalStatus[0] = 2 (OK)
10 (Degraded/Warning), when
OperationalStatus[0] = 3 (Degraded)
One of the following:
Name
System Board
Extender x
Cabinet x Cell y
CIM_PhysicalElement
CreationClassName HP_MemoryBoard
Tag
HPQ:HP_MemoryBoard:x (non-cellular systems), where
x is the board or cartridge number.
HPQ:HP_MemoryBoard:c-x (cellular systems), where c
is the cabinet number and x is the cell number.
One of the following:
Description
System Board
Extender x
Cabinet x Cell y
One of the following:
ElementName
System Board
Extender x
Cabinet x Cell y
CIM_PhysicalPackage
RemovalConditions Removal conditions of the memory board:
When the memory board is the system board:
2 (Not applicable)
When the memory board is not the system board:
3 (Removable when off)
4 (Removable when on or off)
PackageType 9 (Module/Card)
VendorCompatibilityStrings HPQ:HP_MemoryBoard
CIM_Card
True—indicates if this is a baseboard in the
computer system chassis
HostingBoard
False—memory board not on the baseboard
Note: A cell board is considered a baseboard.
HP_MemoryBoard