You can configure email alerts, which will automatically send a message to your mail system when
a problem occurs (see “Email Alerts (Configuration)” on page 122).
The Summary page of the Web Management Interface can indicate an error or warning message,
highlighted by an information, a warning or an error icon against major sub systems. See
Status icons” on page 110.
The System Event Log in the Web Management Interface can also highlight warnings or errors.
See “Log (Status)” on page 130.
TIP:
If you have selected a language other than English and find that some of the messages are in English,
you have upgraded the firmware without upgrading the language pack. This is easily remedied by
following the instructions in “Upgrading the language pack” on page 143. Best practice, however, is
to always upgrade the language pack at the same time as the firmware.
Disk RAID errors and warnings
See “Hard disk replacement” on page 185 for details of hard disk drive failure and rebuild.
Network warnings
See “Connecting to the network” on page 179.
System state
This describes the overall state of the HP D2D.
RAM Failure Warning
Your HP D2D is designed to operate with 16 GB of RAM. If it is outside this limit, a warning will appear.
The device will still operate, but with very limited performance.
Check that the memory modules are correctly mounted in the slots
Check that you have the correct memory capacity inserted
Check that they are in the correct slots
CPU Faulty Warning
You HP D2D is designed to operate with a certain processor and speed. If it is outside this limit, a
warning will appear. The device will still operate, but with very limited performance.
Check that the processor is the correct version
Storage Pool messages
If you have installed the Capacity Upgrade Kit and it is powered off for any reason, you should also
power down the HP D2D Backup System. Then restart the Capacity Upgrade Kit before you restart
the HP D2D Backup System. If the two units are not powered on in the correct sequence, you will get
a message that “a storage pool is not available.
D2D Backup System HP D2D4112 181

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks D2D - Backup Systems and is the answer not in the manual?

HP StorageWorks D2D - Backup Systems Specifications

General IconGeneral
BrandHP
ModelStorageWorks D2D - Backup Systems
CategoryStorage
LanguageEnglish

Related product manuals