l SNMP version
l Community name
l ACL number
l IP address of the NM station
l Equipment administrator's contact information
Procedure
Step 1 Configure available routes between the switch and the NM stations. Details for the configuration
procedure are not provided here.
Step 2 Enable the SNMP agent.
<Quidway> system-view
[Quidway] snmp-agent
Step 3 Configure the switch to run SNMPv1.
[Quidway] snmp-agent sys-info version v1
# Check the configured SNMP version.
[Quidway] display snmp-agent sys-info version
SNMP version running in the system:
SNMPv1 SNMPv3
Step 4 Configure the NM stations' access rights.
# Configure an ACL to allow NMS2 to manage and disallow NMS1 from managing the
switch.
[Quidway] acl 2001
[Quidway-acl-basic-2001] rule 5 permit source 1.1.1.2 0.0.0.0
[Quidway-acl-basic-2001] rule 6 deny source 1.1.1.1 0.0.0.0
[Quidway-acl-basic-2001] quit
# Configure a MIB view and allow NMS2 to manage every MIB object except HGMP on the
switch.
[Quidway] snmp-agent mib-view excluded allexthgmp 1.3.6.1.4.1.2011.6.7
# Configure a community name to allow NMS2 to manage the objects in the MIB view.
[Quidway] snmp-agent community write adminnms2 mib-view allexthgmp acl 2001
Step 5 Configure the trap function.
[Quidway] snmp-agent target-host trap address udp-domain 1.1.1.2 params
securityname 1.1.3.1
[Quidway] snmp-agent trap source Loopback0
[Quidway] snmp-agent trap queue-size 200
[Quidway] snmp-agent trap life 60
Step 6 Configure the equipment administrator's contact information.
[Quidway] snmp-agent sys-info contact call Operator at 010-12345678
Step 7 Configure NMS2.
For details on how to configure NMS2, see the relevant NMS configuration guide.
Step 8 Verify the configuration.
After the configurations are complete, run the following commands to verify that the
configurations have taken effect.
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 1 SNMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
36

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional

Related product manuals