A public SFTP server is configured for the cluster.
5. Run:
snmp-host ip-address
A public SNMP host is configured for the cluster.
NOTE
The member switches in a cluster can communicate with the SNMP server in either of the
following modes:
l Non-NAT: There must be reachable routes between member switches and SNMP server.
l NAT: The cluster-snmp-nat enable command must be run in the cluster view to enable
the SNMP NAT function on the administrator switch. The NAT rules are automatically
generated on the administrator switch, and the member switches obtain the NAT mapped
ports.
The SNMP NAT function on the administrator switch is enabled by default. That is, the member
switches communicate with the SNMP server in NAT mode.
6. Run:
logging-host ip-address
A public log host is configured for the cluster.
Member switches can access the servers and hosts that are configured through Steps
3 to 6 by accessing the administrator switch.
Steps 3 to 6 are optional and are not listed in sequence.
By default, no public server and host is configured for a cluster.
----End
3.4.3 Managing Switches in a Cluster Through HGMP
You can use commands to configure the following features for member switches of an HGMP
cluster in batches: batch distribution, batch restart, incremental configuration, configuration
synchronization, and security features.
Procedure
l Configuring the batch distribution function
Do as follows on the administrator switch:
1. Run:
system-view
The system view is displayed.
2. Run:
cluster
The cluster view is displayed.
3. (Optional) Run:
cluster-plug-play ip ftp-ip-address username user-name password password
[ path-separator pathseparator ]
The default information for logging in to the FTP server is configured.
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 3 HGMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
101

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional