fragments packets :0 , jabbers packets :0
CRC alignment errors:0 , collisions :0
Dropped packet (insufficient resources):1795
Packets received according to length (octets):
64 :150183 , 65-127 :150183 , 128-255 :1383
256-511:3698 , 512-1023:0 , 1024-1518:0
7.4 Maintaining RMON
When an RMON operation fault occurs, you can run the debuggingcommand in the user view
to locate the fault and analyze its cause.
Context
CAUTION
Debugging affects the performance of the system. So, after debugging, run the undo debugging
all command to disable it immediately.
When an RMON fault occurs, run the following debugging command in the user view to locate
the fault.
For the description about the debugging commands, refer to the Quidway S5700 Series Ethernet
Switches Debugging Reference.
Perform the configuration in the user view.
Procedure
l Run the debugging rmon to enable RMON debugging.
----End
7.5 Configuration Examples
This section provides several configuration examples of RMON and RMON2.
7.5.1 Examples for Configuring RMON
Networking Requirements
GigabitEthernet0/0/1 on the Switch belongs to a VLAN.
As shown in Figure 7-1, it is required that the network connected to GigabitEthernet0/0/1 be
monitored to obtain real-time and history statistics of broadcast, multicast, and unknown unicast
packets on the network.
If the number of broadcast, multicast, and unknown unicast packets in the VLAN becomes
abnormal, the Switch sends a Trap message to the NMS.
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 7 RMON Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
400