Step 4 Run:
set constant-ifindex subinterface { dense-mode | sparse-mode }
The memory distribution mode for the sub-interface index is set.
When a sub-interface is created, the system generates an index image file for the sub-interface
in the memory in a specified mode. You may use various sub-interface numbering modes, such
as the continuous mode or the discontinuous mode. In real-world situations, one of the following
distribution modes can be used as needed:
l Sparse mode: applies to discontinuous sub-interface numbering.
l Dense mode: applies to continuous sub-interface numbering.
----End
1.2.7 Checking the Configuration
After SNMPv1 functions are configured, you can view the SNMPv1 configurations.
Prerequisite
The configurations of basic SNMPv1 functions are complete.
Procedure
l Run the display snmp-agent community command to check the configured community
name.
l Run the display snmp-agent sys-info version command to check the enabled SNMP
version.
l Run the display acl acl-number command to check the rules in the specified ACL.
l Run the display snmp-agent mib-view command to check the MIB view.
l Run the display snmp-agent sys-info contact command to check the equipment
administrator's contact information.
l Run the display snmp-agent sys-info location command to check the location of the
device.
l Run the display snmp-agent target-host command to check the information about the
target host.
l Run the display snmp-agent extend error-code status command to check whether the
SNMP extended error code feature is enabled.
l Run the display constant-ifindex configuration command to check the constant interface
index function and relevant configuration information.
----End
1.3 Configuring a Device to Communicate with an NM
Station by Running SNMPv2c
After SNMPv2c is configured, a managed device and an NM station can run SNMPv2c to
communicate with each other. To ensure normal communication, you need to configure both
sides. This section describes only the configurations on a managed device (the agent side). For
details about configurations on an NM station, see the pertaining NM station operation guide.
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 1 SNMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web