sysname Member-2
#
vlan batch 10
#
cluster enable
ntdp enable
ntdp hop 3
ntdp timer 10
ndp enable
#
interface Vlanif10
#
interface GigabitEthernet0/0/1
port link-type trunk
port trunk allow-pass vlan 10
ntdp enable
ndp enable
#
cluster
mngvlanid 10
administrator-address 0001-0001-0001 name HUAWEI
#
return
l Configuration file of Member-3.
#
sysname Member-3
#
vlan batch 10
#
cluster enable
ntdp enable
ntdp hop 3
ntdp timer 10
ndp enable
#
interface Vlanif10
#
interface GigabitEthernet0/0/1
port link-type trunk
port trunk allow-pass vlan 10
ntdp enable
ndp enable
#
cluster
mngvlanid 10
administrator-address 0001-0001-0001 name HUAWEI
#
return
3.6.2 Example for Configuring the Interconnection of FTP Servers
and Devices in and out of the HGMP Cluster (in NAT Mode)
Networking Requirements
As shown in Figure 3-4, all the Layer 2 switches belong to the same cluster. Administrator-1 is
the administrator switch of the cluster and other switches are member switches. The member ID
of Member-1 is 1, the member ID of Member-2 is 2 and the member ID of Member-3 is 3.
To upload files to Member-1, Member-2, and Member-3 or download files from them, you can
set up an FTP connection between the devices out of the cluster and member switches in NAT
or non-NAT mode.
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 3 HGMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential