l To perform the NQA test at the specified time, run the start at [ yyyy/mm/dd ] hh:mm:ss
[ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime
{ seconds second | hh:mm:ss } } ] command.
The test instance is started at a specified time.
l To perform the NQA test after a certain delay period, run the start delay { seconds second
| hh:mm:ss } [ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } |
lifetime { seconds second | hh:mm:ss } } ] command.
The test instance is started after a certain delay.
The differences between the TCP Public tests and the TCP Private tests are as follows:
l The TCP Public tests do not require the destination port to be configured on the client.
Connection requests are initiated and sent to the TCP port 7 of the destination address. The
server should monitor the TCP port 7.
l The TCP Private tests require the destination port be specified and the related monitoring
services enabled on the server.
----End
6.12.4 Checking the Configuration
After configuring the TCP test, you can view the test result.
Prerequisite
The configurations of the TCP Test function are complete.
Context
NOTE
NQA test results cannot be displayed automatically on a terminal. You must run the display nqa results
command to view test results. By the default, the command output contains the records about only the last
five tests.
Procedure
l Run the display nqa results [ test-instance admin-name test-name ] command to view the
test results on the NQA client.
l Run the display nqa-server command to view the information about the NQA server.
----End
Example
Run the display nqa results command. If the test is successful, the following is displayed.
<Quidway> display nqa results
NQA entry(admin, tcp) :testflag is inactive ,testtype is tcp
1 . Test 1 result The test is finished
Send operation times: 3 Receive response times: 3
Completion:success RTD OverThresholds number: 0
Attempts number:0 Drop operation number:0
Disconnect operation number:0 Operation timeout number:0
System busy operation number:0 Connection fail number:0
Operation sequence errors number:0 RTT Stats errors number:0
Destination ip address:10.2.1.2
Min/Max/Average Completion Time: 31/62/51
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 6 NQA Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
283

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional