Do as follows on the switch on which traffic statistics should be collected:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface { | gigabitethernet | xgigabitethernet } interface-number
The interface view is displayed.
Step 3 Run:
rmon history entry-number buckets number interval sampling-interval [ owner owner-
name ]
The historyControlTable is configured.
----End
7.3.5 Configuring the EventTable
After EventTable is configured, when the number of events exceeds the alarm threshold, the
router generates logs, sends traps, or generates logs and sends traps.
Context
Do as follows on the switch that is monitored:
The RMON event management module is responsible for adding events to the corresponding
rows in the eventTable and defining the methods of processing events:
l log: sending only logs
l log-trap: sending both logs and trap messages to the NM Station
l none: marking that no event occurs
l trap: sending trap messages to the NM Station
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
rmon event entry-number [ description string ] { log | trap object | log-trap
object | none } [ owner owner-name ]
The eventTable is configured.
----End
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 7 RMON Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
396

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional

Related product manuals