1. Run:
system-view
The system view is displayed.
2. Run:
ntdp timer hop-delay hop-delay-time
The hop delay in forwarding NTDP packets is set.
3. Run:
ntdp timer port-delay port-delay-time
The interface delay in forwarding NTDP packets is set.
By default, the hop delay is 200 ms and the interface delay is 20 ms.
l (Optional) Setting the interval for collecting topology information
1. Run:
system-view
The system view is displayed.
2. Run:
ntdp timer interval
The interval for collecting topology information is set.
By default, the interval for collecting topology information is set to 0 minutes, that is,
topology information is not collected regularly.
l (Optional) Enabling topology collection
1. Run the following command in the user view:
ntdp explore
Topology collection is enabled.
You can run this command to collect topology information at any time.
----End
3.3.4 Creating a Cluster
To perform unified management over switches, you must first create a cluster and add switches
to be managed to the cluster.
Procedure
l Configuring a management VLAN
Do as follows on the administrator switch and member switches:
1. Run:
system-view
The system view is displayed.
2. Run:
vlan vlan-id
A VLAN is created and the VLAN view is displayed.
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 3 HGMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
89

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional

Related product manuals