Pre-configuration Tasks
Before configuring RMON, complete the following tasks:
l Configuring parameters for Ethernet interfaces
l Configuring basic SNMP functions
Data Preparation
To configure RMON, you need the following data.
No. Data
1 Interface on which the statistics function is enabled
2 Statistics table to be used and related parameters
3 HistoryControl table to be used and related parameters
4 Event table to be used and related parameters
5 Alarm table to be used and related parameters
6 Prialarm table to be used and related parameters
7.3.2 Enabling the RMON Statistics Function on the Interface
You need to enable traffic statistics function on the interface where traffic statistics are collected.
If the traffic statistics function is not enabled on the interface, statistics values of in both
ethernetStatsTable and HistoryControlTable are 0.
Context
Do as follows on the switch on which traffic statistics should be collected:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface { gigabitethernet | xgigabitethernet } interface-number
The interface view is displayed.
Step 3 Run:
rmon-statistics enable
The RMON statistics function is enabled on the interface.
If the statistics function is not enabled on the interface, the statistics value in ethernetStatsTable
and historyControlTable of RMON is 0.
----End
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 7 RMON Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
394

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional

Related product manuals