l To configure the padding character of the packet, run the datafill fillstring command.
l To configure the interval for sending test packets, run the interval seconds interval
command.
l To configure the percentage of the failed NQA tests, run the fail-percent percent command.
Step 7 Run:
start
The NQA test is started.
Select the start mode as required because the startcommand has several forms.
l To perform the NQA test immediately, run the start now [ end { at [ yyyy/mm/dd ]
hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime { seconds second | hh:mm:ss } } ]
command.
The test instance is started immediately.
l To perform the NQA test at the specified time, run the start at [ yyyy/mm/dd ] hh:mm:ss
[ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime
{ seconds second | hh:mm:ss } } ] command.
The test instance is started at a specified time.
l To perform the NQA test after a certain delay period, run the start delay { seconds second
| hh:mm:ss } [ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } |
lifetime { seconds second | hh:mm:ss } } ] command.
The test instance is started after a certain delay.
----End
6.15.3 Checking the Configuration
After configuring the LSP ping test, you can view the test result.
Prerequisite
The configurations of the LSP Ping Test function are complete.
Context
NOTE
NQA test results cannot be displayed automatically on a terminal. You must run the display nqa results
command to view test results. By the default, the command output contains the records about only the last
five tests.
Procedure
l Run the display nqa results command to view the test results on the NQA client.
----End
Example
Run the display nqa results command. If the test is successful, the following is displayed.
l Statistics about errors
Number of unroutable connections
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 6 NQA Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
294

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional

Related product manuals