NOTE
The private IP addresses used by a cluster cannot be the same as any IP address on the device.
4. Run:
auto-build [ recover ]
A cluster is created automatically.
The auto-build command can also be used to add member switches automatically.
For configuration details, see Adding a Member Switch.
----End
3.3.5 Adding a Member Switch
To perform unified management over a switch that is not a member of a cluster, you must first
add the switch to the cluster.
Context
After a cluster is set up, you can add a member switch to the cluster either manually or
automatically.
Procedure
l Adding a member switch manually
In this mode, you must manually specify the MAC address of the member switch.
Do as follows only on the administrator switch:
1. Run:
system-view
The system view is displayed.
2. Run:
cluster
The cluster view is displayed.
3. Run:
add-member [ member-number ] mac-address mac-address [ password password]
A member switch is added.
l Adding a member switch automatically
In this mode, the administrator switch prompts you whether to add all the existing candidate
switches to the cluster. If the authentication mode is used to add member switches, the
administrator switch quits the action of adding a member switch.
Do as follows only on the administrator switch:
1. Run:
system-view
The system view is displayed.
2. Run:
cluster
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 3 HGMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
92

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs