The system view is displayed.
2. Run:
cluster
The cluster view is displayed.
3. Run:
cluster-member unrelated-port [ group-by { device-type device-type | ip
{ip-address [ to ip-address ] } &<1-10> | member-number { member-number
[ to member-number ] } &<1-10> } ] { ndp | ntdp }
NDP or NTDP is disabled on unrelated interfaces.
Only the last command execution result is saved.
The member selection mode can be device type-based, member switch ID-based,
IP address-based, or all.
This command can be performed only after the cluster is enabled.
----End
3.4.4 Checking the Configuration
After configuring advanced HGMP functions, you can view the configuration.
Prerequisite
The configurations of the Advanced HGMP are complete.
Procedure
l Run the display cluster-increment-result to check the delivery of incremental
configuration.
l Run the display cluster-license to check the cluster license.
l Run the display cluster-topology-info to check the cluster topology.
l Run the display increment-command to check the incremental configuration command.
l Run the display increment-synchronization-result to check whether configuration files
of member switches are synchronized to the FTP server.
l Run the display member-getfile-state to check whether member switches successfully
obtain configuration files, version files, or patch files.
l Run the display member-interface-state { ndp | ntdp } to check the status of NDP or
NTDP on unrelated interfaces of member switches.
l Run the display member-reboot-state to check whether member switches are restarted
successfully.
l Run the display member-save-state to check whether member switches successfully save
the current configurations to the FTP server
l Run the display synchronization-result to check whether member switches successfully
synchronize configuration files to the FTP server.
----End
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 3 HGMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
105

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional