The ID of the authentication key used for the synchronization of the clocks on the NAT peer is
configured.
----End
4.4.6 Configuring NTP Authentication in Broadcast Mode
By configuring the authentication key ID used in the synchronization with the NTP broadcast
server on the local switch, you can apply NTP authentication in broadcast mode.
Context
Do as follows on the switch that functions as an NTP broadcast server.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
vlan vlan-id
A VLAN is created and the VLAN view is displayed.
Step 3 Run:
interface vlanif vlan-id
The interface that receives NTP broadcast packets is specified.
Step 4 Run:
ntp-service broadcast-server [ authentication-keyid key-id | version number ] *
The ID of the authentication key used by the NTP broadcast server is configured.
For configuring the broadcast client, see Configuring the Broadcast Mode.
----End
4.4.7 Configuring NTP Authentication in Multicast Mode
By configuring the authentication key ID used in the synchronization with the NTP multicast
server on the local switch, you can apply NTP authentication in multicast mode.
Context
Do as follows on the switch that functions as an NTP multicast server.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 4 NTP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
226

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional