When a sub-interface is created, the system generates an index image file for the sub-interface
in the memory in a specified mode. You may use various sub-interface numbering modes, such
as the continuous mode or the discontinuous mode. In real-world situations, one of the following
distribution modes can be used as needed:
l Sparse mode: applies to discontinuous sub-interface numbering.
l Dense mode: applies to continuous sub-interface numbering.
----End
1.3.7 Checking the Configuration
After SNMPv2c functions are configured, you can view the SNMPv2c configurations.
Prerequisite
The configurations of basic SNMPv2c functions are complete.
Procedure
l Run the display snmp-agent community command to check the configured community
name.
l Run the display snmp-agent sys-info version command to check the enabled SNMP
version.
l Run the display acl acl-number command to check the rules in the specified ACL.
l Run the display snmp-agent mib-view command to check the MIB view.
l Run the display snmp-agent sys-info contact command to check the equipment
administrator's contact information.
l Run the display snmp-agent sys-info location command to check the location of the
device.
l Run the display snmp-agent target-host command to check information about the target
host.
l Run the display snmp-agent inform [ address udp-domain ip-address [ vpn-instance
vpn-instance-name ] params securityname security-string ] command to check inform
parameters and device statistics with the NM station being specified or not.
l Run the display snmp-agent notification-log info command to check alarm logs stored
in the log buffer.
l Run the display snmp-agent extend error-code status command to check whether the
SNMP extended error code feature is enabled.
l Run the display constant-ifindex configuration command to check the constant interface
index function and relevant configuration information.
----End
1.4 Configuring a Device to Communicate with an NM
Station by Running SNMPv3
After SNMPv3 is configured, a managed device and an NM station can run SNMPv3 to
communicate with each other. To ensure normal communication, you need to configure both
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 1 SNMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
25

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional