EasyManua.ls Logo

Huawei Quidway S5700 Series - Checking the Configuration; Configuring a Device to Communicate with an NM Station by Running Snmpv3

Huawei Quidway S5700 Series
415 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
When a sub-interface is created, the system generates an index image file for the sub-interface
in the memory in a specified mode. You may use various sub-interface numbering modes, such
as the continuous mode or the discontinuous mode. In real-world situations, one of the following
distribution modes can be used as needed:
l Sparse mode: applies to discontinuous sub-interface numbering.
l Dense mode: applies to continuous sub-interface numbering.
----End
1.3.7 Checking the Configuration
After SNMPv2c functions are configured, you can view the SNMPv2c configurations.
Prerequisite
The configurations of basic SNMPv2c functions are complete.
Procedure
l Run the display snmp-agent community command to check the configured community
name.
l Run the display snmp-agent sys-info version command to check the enabled SNMP
version.
l Run the display acl acl-number command to check the rules in the specified ACL.
l Run the display snmp-agent mib-view command to check the MIB view.
l Run the display snmp-agent sys-info contact command to check the equipment
administrator's contact information.
l Run the display snmp-agent sys-info location command to check the location of the
device.
l Run the display snmp-agent target-host command to check information about the target
host.
l Run the display snmp-agent inform [ address udp-domain ip-address [ vpn-instance
vpn-instance-name ] params securityname security-string ] command to check inform
parameters and device statistics with the NM station being specified or not.
l Run the display snmp-agent notification-log info command to check alarm logs stored
in the log buffer.
l Run the display snmp-agent extend error-code status command to check whether the
SNMP extended error code feature is enabled.
l Run the display constant-ifindex configuration command to check the constant interface
index function and relevant configuration information.
----End
1.4 Configuring a Device to Communicate with an NM
Station by Running SNMPv3
After SNMPv3 is configured, a managed device and an NM station can run SNMPv3 to
communicate with each other. To ensure normal communication, you need to configure both
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 1 SNMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
25

Table of Contents

Related product manuals