After the configuration, the configured information is used by default during the
process of batch distribution.
4. (Optional) Run:
cluster-member ftp-timeout time
The timeout period for member switches to download the configuration file, the
version file or the patch files through FTP is configured.
5. Run:
cluster-member [ group-by { device-type device-type | ip {ip-address [ to
ip-address ] } &<1-10> | member-number { member-number [ to member-
number ] } &<1-10> } ] get { configuration-file | system-software | patch
| paf | license } file-name [ ip ftp-ip-address user-name user-name
password password ] [ path-separator pathseparator ]
The batch distribution function is performed.
During the process of batch distribution, the group-by command can be used to
specify member switch groups according to different selection modes.
If Step 3 is not performed, you must enter the IP address, user name, and password
when using this command.
If Step 3 is performed, the IP address, user name, and password configured in Step
3 are used by default.
IP addresses used in batch distribution are private IP addresses used in the cluster.
l Configuring the batch restart function
Do as follows on the administrator switch:
1. Run:
system-view
The system view is displayed.
2. Run:
cluster
The cluster view is displayed.
3. (Optional) Run:
cluster-member reboot-timeout time
The timeout period for member switches to reboot is configured.
4. Run:
cluster-member reboot [ group-by { device-type device-type | ip {ip-
address [ to ip-address ] } &<1-10> | member-number { member-number [ to
member-number ] } &<1-10> } ]
The batch restart function is performed.
The current configuration of the device is not saved during the process of batch restart.
l Configuring the plug-and-play function
Do as follows on the administrator switch:
1. Run:
system-view
The system view is displayed.
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 3 HGMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
102

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional

Related product manuals